Permanent Magnetism Material Auto-testing Equipment
TYU-2000H style Permanent Magnetism Material Auto-testing Equipment of Hunan Loudi Tianyu Electronic Co.,LTD was released after many years of elaborative design by our scientific research personnel, which is made on the basis of MATS-2000 style Permanent Magnetism Material Auto-testing Equipment(Original style) according to the development of the software and hardware technology.
It can suitable for the testing of ordinary Permanent Magnetism Material (Such as Al Ni & Co, ferrite and making bonded magnet) and it also suitable for testing strong-magnetic-field Permanent Magnetism Material (eg Nd-Fe-B). All the measure process can be finished automatically except sample placement. Compared with the traditional method, the testing of TYU-2000H style Permanent Magnetism Material Auto-testing Equipment is more reasonable, quicker, effective and good digital repeatability because the application of the computer's technique is maximally adopted, for example, the automatic modification of integrator zero point drifting, the modification of hall nonlinearity, the technology of special excitation waveform design and the technology of software digital filter.
The popular graphical interface is adopted by the testing software of this equipment, so it can run under the WindowsXP/2000/98 operating system. This kind of interface is very simple and easy to learn and operate. The testing software is green software, with no installation, no operation to the system registration form. It can run directly.
The Key Technical Indexes
|
Device Name |
TYU-2000H Style Permanent Magnetism Material Auto-testing Equipment
|
|
Measuring Material |
Ordinary permanent magnet(AlNiCo, Ferrite and so on) and strong-magnetic-field Permanent Magnetism Material (eg Nd-Fe-B) |
|
Standard Requirement |
National Standard GB/T 3217-92 and IEC standard IEC 404-5 |
|
Measurement Parameters |
Br,Hcb,Hcj(Hci),(BH)m,Js,Magnetic Hysteresis Loop and Demagnetization Curve |
|
Size of Sample |
Standard Configuration: Roundness & Squareness, Φ4-Φ100mm,the thickness of samples over 3mm,. Corresponding size of the electromagnet can be chose if the size of sample is larger. |
|
Shape of Sample |
The shape of the tested sample: Rectangular, squareness, roundness, tile shape(tile shape pole-head) all is OK. |
|
Measuring Method |
Magnetic Induction- B loop & J loop + Fluxmeter MeasurementMagnetic Field- adopt Hall sheet + Gaussmeter Measurement or J loop (Two measure methods can be chose) |
|
Measuring Time |
Measuring and magnetizing can be finished full automaticly . It can be finished once off. The fastest testing rate is 50secs. |
|
Measuring Process |
The eddy current field can be avoided and the phase angle which made by the magnetic field and magnetic polarization can be eliminated for the Quasi static state. so that the magnetization of the samples can be homogeneous. |
|
Temperature Range |
Under room temperature , the device which had the temperature controlled device can be chose to measure the demagnetization curve and analyze the temperature characteristic of the material. |
|
Adjustment |
This device can amend the temperature coefficient of the measured parameter and the measuring range coefficient automatically. |
|
Measurement Error |
Repetition: Br、Hcj、Hcb is ±0.3%、BHm is ±0.5%;
Incertitude Degree: Br、Hcj、Hcb is 1.0%、BHmis 2.0%; |
|
Electromagnet |
TYU-130 stye, One set of Φ130 pure iron pole-head, vertical structure, pole rodΦ130, the gap between the pole-head is adjustable from 0-60mm, the maximum electromagnetic field: 1.5T(Gap 10mm) (Φ130 pure iron pole-head)~2.8T(gap 10mm)(Shrink Pole-head), alsoΦ100~Φ250 type electromagnet can be offered. | |
Device Arrangement
|
Computer |
The computer adopt the popular Standard configuration of the market. Customers can have some choices if there is other requirement. |
|
Printer |
Laser printer or color ink jet printer can be chose. |
|
AD/DA |
RS232 or USB interface |
|
Magnetized Power Source |
DC;70V;30A、50A can be chose,over voltage、over current、short-circuit protection, high stability |
|
Fluxmeter B |
Small Zero excursion, convenience for adjustment |
|
Gauss H |
One hall probe, low nonlinearity of the probe, small excursion of the temperature, the four files of the measurement range can shift automatically, the samples can be measured accurately no matter it is big or small. |
|
Electromagnet |
TYU-130 tyle and the base of the electromagnet,vertical structure,pole rod 130, The adjustable range between two pole-heads is 0-60mm。 magnetic field is 1.5T---2.8T(gap 10mm,Φ130 pure iron pole-head )can be chose. |
|
J loop |
Can be made according to customers’ requirements. |
|
Measuring Software |
The Chineselization of the measuring software adapt to work under WIN98/2000/XP.The Chinese indication can be followed during the whole process and it can realize the high-speed output of the date. Besides, complex font edition can be chose. |
|
|
The instruction of using and maintenance. vulnerable component |
The Selection of Electromagnet
|
Choosing the suitable Electromagnet should according to the size of the real samples which is going to be measured. Please refer the following table. |
|
Measuring Electromagnet(The Series of Variable Air Gap) |
|
Type |
Maximum Magnetic Field |
Diameter of the polar |
Adjustable Range of
the Air Gap |
|
TYU-100 |
1.5T~2.8T(10mm Air Gap) |
Φ100 |
0~50mm |
|
TYU-130 |
1.5T~2.8T(10mm Air Gap) |
Φ130 |
0~50mm |
|
TYU-150 |
1.5T~2.8T(10mm Air Gap) |
Φ150 |
0~50mm |
|
TYU-200 |
1.5T~2.8T(10mm Air Gap) |
Φ200 |
0~50mm |
|
TYU-250 |
1.5T~2.8T(10mm Air Gap) |
Φ250 |
0~50mm | |